The Florida Building Code - Plumbing, Chapter 4 covers all requirements for fixtures, faucets, and fixture fittings in residential and commercial buildings. This chapter is important to consider when installing two bathroom sinks with one drain, as it outlines the standards for proper installation and functionality. According to the Florida Building Code, all fixtures must be approved by the International Association of Plumbing and Mechanical Officials (IAPMO) or the International Code Council (ICC). This ensures that the fixtures meet safety and performance standards. When it comes to bathroom sinks, the Florida Building Code requires that they must be equipped with an overflow drain to prevent overfilling. This is an important safety feature to prevent flooding and damage to the sink and surrounding areas. Additionally, the code states that all faucets must have a flow rate of no more than 2.2 gallons per minute (gpm). This helps conserve water and reduce utility costs for the building. In terms of fixture fittings, the Florida Building Code requires that all fittings must be made of durable, non-corrosive material and be properly sized for the fixture. This ensures longevity and proper functioning of the fixtures.Florida Building Code - Plumbing, Chapter 4: Fixtures, Faucets and Fixture Fittings
Chapter 10 of the Florida Building Code covers traps, interceptors, and separators, which are all important components of a plumbing system. These are especially important to consider when installing two bathroom sinks with one drain, as they help prevent clogs and maintain proper drainage. The code requires that all fixtures must be equipped with a trap, which is a curved section of pipe that holds water and prevents sewer gases from entering the building. This is important for maintaining proper indoor air quality. Interceptors and separators are used to remove pollutants and debris from wastewater before it is discharged into the sewer system. The Florida Building Code outlines specific requirements for the installation and maintenance of these devices to ensure proper functioning and compliance with environmental regulations.Florida Building Code - Plumbing, Chapter 10: Traps, Interceptors and Separators
Chapter 11 of the Florida Building Code covers storm drainage systems, which are designed to remove rainwater and other surface water from a building's property. This chapter is important to consider when installing two bathroom sinks with one drain, as it outlines requirements for proper drainage and prevention of water damage. The code requires that all storm drainage systems must be designed to handle a 25-year storm event, which is a storm with a 4% chance of occurring in any given year. This ensures that the system can effectively handle heavy rainfall without causing flooding or damage to the building. In addition, the code outlines specific requirements for the design, installation, and maintenance of roof drainage systems, including gutters, downspouts, and scuppers. These systems are important for directing rainwater away from the building and preventing damage to the foundation and surrounding areas.Florida Building Code - Plumbing, Chapter 11: Storm Drainage
Chapter 12 of the Florida Building Code covers fuel gas piping, which is used to supply fuel gas (such as natural gas or propane) to appliances in a building. This chapter is important to consider when installing two bathroom sinks with one drain, as it outlines requirements for proper installation and safety. The code requires that all fuel gas piping must be installed by a licensed professional and must comply with the National Fuel Gas Code. This ensures that the piping is properly sized and installed to prevent leaks and potential hazards. In addition, the code requires that fuel gas piping must be protected from damage and corrosion and must be equipped with shut-off valves for each appliance. This helps ensure the safety and functionality of the fuel gas system.Florida Building Code - Plumbing, Chapter 12: Fuel Gas Piping
Chapter 13 of the Florida Building Code covers requirements for health care facilities and medical gas and vacuum systems. This chapter is important to consider when installing two bathroom sinks with one drain in a health care facility, as it outlines specific requirements for these types of buildings. The code requires that all health care facilities must have a medical gas and vacuum system installed by a licensed professional. This system supplies oxygen, nitrous oxide, and other medical gases to patients and must comply with the National Fire Protection Association's standards. In addition, the code requires that all plumbing fixtures in a health care facility must be equipped with a backflow prevention device to prevent contamination of the medical gas and vacuum system. This is crucial for maintaining a safe and sanitary environment for patients and staff.Florida Building Code - Plumbing, Chapter 13: Health Care Facilities and Medical Gas and Vacuum Systems
Chapter 14 of the Florida Building Code lists all referenced standards that must be followed when installing plumbing systems in a building. These standards cover a wide range of topics, such as materials, testing, and installation methods. Some important referenced standards to consider when installing two bathroom sinks with one drain include the Uniform Plumbing Code, the International Plumbing Code, and the National Standard Plumbing Code. These standards provide guidance on proper installation techniques and ensure compliance with safety and performance standards.Florida Building Code - Plumbing, Chapter 14: Referenced Standards
Chapter 15 of the Florida Building Code lists additional referenced standards that must be followed for specific types of plumbing systems, such as water supply systems, drain and vent systems, and water heaters. It is important to consult these referenced standards when installing two bathroom sinks with one drain, as they provide detailed requirements for each component of the plumbing system. This helps ensure that the installation is done correctly and meets all necessary standards and regulations.Florida Building Code - Plumbing, Chapter 15: Referenced Standards
Chapter 16 of the Florida Building Code lists referenced standards for plumbing fixtures and fixture fittings. These standards cover topics such as materials, testing, and performance requirements. It is crucial to follow these standards when installing two bathroom sinks with one drain, as they ensure that the fixtures are of high quality and will function properly. This helps prevent potential issues and ensures longevity of the fixtures.Florida Building Code - Plumbing, Chapter 16: Referenced Standards
Chapter 17 of the Florida Building Code lists referenced standards for backflow prevention devices, which are crucial for maintaining the safety and quality of a building's water supply. These standards cover topics such as materials, testing, and installation requirements. It is important to adhere to these standards when installing two bathroom sinks with one drain, as backflow prevention devices are necessary to prevent contamination of the building's water supply. This is especially important in commercial buildings, where there may be a higher risk of cross-contamination.Florida Building Code - Plumbing, Chapter 17: Referenced Standards
Chapter 18 of the Florida Building Code lists referenced standards for alternative water sources, such as rainwater harvesting systems and greywater recycling systems. These systems are becoming increasingly popular for their environmental and cost-saving benefits. If installing two bathroom sinks with one drain in a building with an alternative water source, it is important to follow these referenced standards to ensure the proper design, installation, and maintenance of the system. This helps ensure that the alternative water source is used safely and effectively.Florida Building Code - Plumbing, Chapter 18: Referenced Standards